Temperature sensor with transmit device Temperature: Pt 100 (2-, 3-, 4-wire) Accuracy: class A - B - 1/2 DIN Measuring range: -40...+80 °C Humidity: 0...100 %rF Output humidity: 4...20 mA / 0...10 V / 2...10 V Connection: via screwed cable gland to terminal screws Enclosure: cast aluminium Optional: transmitter 4...20 mA / 2...10 V / 0...10 V Optional: Indicator (Input: 4...20 mA) |
Channel Humidity sensor Range humidity: 0...100% relative humudity Range temperature: 0...+40°C/+50°C/+100°C, -10...+90°C, -30...+60°C Operating range humidity: +10...+95% relative humidity Operating range temperature: -30...+80°C Medium: unpressurized,non aggressive, non condensing air Output: 0...20mA or 0...10V (3-/4-wire) / 4...20mA (2-wire) Supply voltage: 15...30VDC or 24VAC Accuracy: +/- 3,5% rH, +/- 0,8°K |
Modular intelligent Weather station Reliable detection of all aqueous precipitation 1 switching contact "heating on" Serial interface, galvanically insulated 1 input rail temperature (4...20 mA) Quadruple analogue output optionally for air temperature, relative air, humidity, intensity of precipitation and air pressure Intelligent self adjustment in case of soiling Internal heating effective down to -30°C Optional mounting device, galvanized Optional display in cover of case. |
Silo load cell type: SILO | ID: SI technical features Ranges from 1 t up to 75 t Output 2mV/V Supply voltage 10VDC Accuracy below 0,05% of and scale value Degree of protection IP68 Insensitive to off axis loads Highly accurate and reliable optionally made of stainless steel |
Tension load cell Standard capacity from 100kg (250lb) to 5000kg (20klb) S-shaped tension load cell for simple mounting High alloy tool steel, nickel plated or stainless steel design Particularly suitable for parallel connection Optimal cost-performance ratio Degree of protection IP66 Accuracy 0,02% end of scale value |
Annular load cell Nominal load: 10 kN up to 200 kN Output: strain gauge full bridge, 1 mV/V Voltage supply: 10 VDC Accuracy: +/- 0,5% of range Temperature range: -20...+80 °C Safe overload: 150% of nominal range Material: stainless steel ARMCO 17-4PH Protection: IP66 Connection: 3 m cable |
Rail temperature sensor Measurement element: Pt100, 4-wire, Class A Resolution: 0,1 °C Configuration: with PC, MS - Windows 3.11 or higher Operating surface "DTM - Control" Analog output 4...20 mA, invertable, 2-wire technics Temperature linear output Galvanic insulation Special steel case completely potted |
Cable resistance thermometer with sleeve socket and GL –approval Sensor RTD: 1x PT100 / 1x Pt1000 / 2x Pt100 / 2x Pt1000 (2-, 3-, 4-wire) Accuracy: class A / class B / B1/2DIN / B1/3DIN / B1/10DIN Protective sheathing: stainless steel 1.4571, diameter: 4 / 5 / 6 mm Nominal length: 25 (d = 4) / 45 (d=4, d = 5) / 41 (d = 6) / 65 (d = 6) mm Option: other length Cable length: 2000 mm / Option: other length Cable: PVC-PVC / PTFE-silicone / PTFE-PTFE / PTFE-braiding-PTFE, Fibre glass-stainless steel braiding Antikink: heat shrinkable sleeve / spring / without Connection: open ends |
お問合わせ先:代理店: 有限会社ナックス 669-1545 兵庫県三田市挟間が丘2-16-27 電話079(563)4146 FAX 079(563)1404 担当: 奥村文夫
NACS LTD 2-16-27, HAZAMAGAOKA,SANDA,HYOGO,669-1545, JAPAN Email: fumio_okumura@nacsnet.co.jp
|
Load cell |
Level sensor |
Flow sensor |
IO-Link sensors & transmitter |
Temperature and Humidity Sensor |
Intrinsically safe level sensor HART | GL- and Ex-approval |